{"product_id":"91136800-cue-controls-variable-frequency-drives","title":"#91136800 Cue Controls Variable Frequency Drives","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eThis item is obsolete. Contact us for replacement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eGrundfos Part #91136800 Cue Controls Variable Frequency Drives , 3 x 200-240V, 74.8 CUE OUTPUT AMPS, 20 SUB MOTOR RATED HP, IP21 ENCLOSURE RATING, B4 ENCLOSURE SIZE.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGRUNDFOS CUE\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eComprehensive range. Superior features. With over 100 different configuration possibilities, covering a power range from 0.55 kW to 250 kW, CUE represents one of the most comprehensive and versatile ranges of frequency converters for pump applications currently on the market. The CUE range is available with 5 different power supplies, 2 enclosure classes IP20\/21 (Nema 1) \/ IP55 (Nema 12), and no less than 24 different\u003c\/li\u003e\n\u003cli\u003eoutput powers. So whatever you need, there is a suitable CUE solution for the job at hand. What’s more, CUE is packed with splendid features that provide maximum convenience and enhanced operational ease. Just take\u003c\/li\u003e\n\u003cli\u003ea look at the added value you get with CUE. Intuitive start-up guide\u003c\/li\u003e\n\u003cli\u003eThe CUE start-up guide enables easy installation and commissioning,\u003c\/li\u003e\n\u003cli\u003eand plug-and-pump convenience. Only a few settings need to be specified by the installer on-site, the rest of the set-up is either done automatically or factory preset. (Read more on page 8). Smart user interface The unique and user-friendly operating panel consists of a graphical display with backlight and buttons for pump start\/stop, navigation, and menu settings. You get the same “look and feel” with\u003c\/li\u003e\n\u003cli\u003eCUE as with our other E-solutions in that user interface and menu\u003c\/li\u003e\n\u003cli\u003estructure are identical to the familiar R100 operating panel used in connection with E-pumps. So in fact, operating a CUE solution is just like operating an E-pump. Automatic direction of rotation A CUE solution offers automatic detection and setting of correct direction of rotation. During the start-up, CUE will automatically check the direction of rotation and ensure that the pump is running in the right direction. If the direction of rotation is wrong, CUE will change the direction electronically, thus making manual interchange of motor wires unnecessary.\u003c\/li\u003e\n\u003cli\u003eConstant – whatever you want When we say constant, we mean constant! CUE has a built-in PI controller that provides closed-loop control of whatever value you want to control: Constant pressure with or without stop function With stop function: The head is kept constant at high flow.\u003c\/li\u003e\n\u003cli\u003eOn\/off operation at low flow. Without stop function: The pressure is kept constant irrespective of the flow. Constant differential pressure The differential pressure is kept constant irrespective of the flow. Proportional pressure The head is reduced at low flow and increased at high flow. Constant level with or without stop function With stop function: The fluid level is kept constant at high flow. On\/off operation at low flow. Without stop function: The fluid level is kept constant\u003c\/li\u003e\n\u003cli\u003eirrespective of the flow. Constant temperature The fluid temperature is kept constant irrespective of the flow.Proportional pressure The proportional pressure function ensures that the differential pressure in a circulating application, e.g. a heating or an air-conditioning system, is sufficient at low-flow as well as at high-flow demands. The differential pressure is automatically raised with increased flow.\u003c\/li\u003e\n\u003cli\u003eStop function In most water supply applications the required flow can be\u003c\/li\u003e\n\u003cli\u003every low, sometimes even equal to zero. In those situations on\/off operation of the pump according to demand is more economical. CUE offers a stop function for constant pressure or constant level applications. The stop function furthermore prevents the pump from running against closed valve with the risk of heating up the water in the pump, and thus growth of unhealthy bacteria or damage of the shaft seal. Dry-running protection\u003c\/li\u003e\n\u003cli\u003eCUE offers protection against dry running, as one of the inputs can be dedicated to a dry-running detector. Duty\/standby By interconnecting two CUE converters via the standard built-in GENIbus interface, a duty\/standby function of the two pumps can be obtained. Motor bearings supervision CUE has a motor bearings monitoring function that displays an automatic warning when it is time for relubrication or replacement of bearings. This function can be further optimised by the addition of bearings temperature measurement (requires an IO module), which provides a\u003c\/li\u003e\n\u003cli\u003ewarning or discontinues pump operations automatically in case of overheating.\u003c\/li\u003e\n\u003cli\u003esmart user interface CUE offers quick and easy set-up and commissioning\u003c\/li\u003e\n\u003cli\u003ecompared to a standard frequency converter, because it only requires very few settings at start-up. Simply key in application-specific variables such as motor data, pump family, control function (e.g. constant pressure), sensor type, and setpoint, and CUE will automatically set all necessary parameters; i.e. ramp times, min. speed, controller constants,\u003c\/li\u003e\n\u003cli\u003eavailable functions, and so on. After completing the start-up guide, CUE’s menu structure is equivalent to the R100 menu structure used in connection with Grundfos E-pumps.\u003c\/li\u003e\n\u003cli\u003eTHE COMPREHENS IVE CUE RANGE\u003c\/li\u003e\n\u003cli\u003eWhen opting for a CUE solution you get the choice of the following versions of CUE; all available in two enclosure classes IP20\/21 (Nema1) or IP55 (Nema12):\u003c\/li\u003e\n\u003cli\u003e1-phase, 1x200-240 V, 50\/60 Hz (1.1-7.5 kW), C1\u003c\/li\u003e\n\u003cli\u003e3-phase, 3x200-240 V, 50\/60 Hz (0.75 - 45 kW), C1\u003c\/li\u003e\n\u003cli\u003e3-phase, 3x380-500 V, 50\/60 Hz (0.55 - 250 kW),C1 up to 90 kW, C2 above 90 kW\u003c\/li\u003e\n\u003cli\u003e·\u003c\/li\u003e\n\u003cli\u003e3-phase, 3x525-600 V, 50\/60 Hz (0.75– 7.5 kW), C3\u003c\/li\u003e\n\u003cli\u003e3-phase, 3x525-690 V, 50\/60 Hz (11 - 250 kW), C3\u003c\/li\u003e\n\u003cli\u003eC1: units with built-in EMC filter for normal household applications. C2: units with built-in EMC filters for industrial applications. C3: units without EMC filter (only applicable in industrial applications).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFour digital inputs\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOne dedicated input for external start\/stop.\u003c\/li\u003e\n\u003cli\u003eRemaining inputs can be set to: Min. (min. curve), Max. (max. curve), Ext. fault (external fault), Flow switch, Alarm reset, Dry running (from external sensor), Not active, Three analogue inputs, One 0-10 V input for external setpoint. One 0\/4-20 mA input for sensor feedback. One dditional 0\/4-20 mA input for sensor (requires an additional IO module). Two Pt100\/1000 inputs To be used in connection with motor bearings temperature\u003c\/li\u003e\n\u003cli\u003emeasurement, or alternative temperature measurement such as the media temperature (requires an additional IO module). One analogue output\u003c\/li\u003e\n\u003cli\u003eCan be set to indicate different parameters such as speed,Two digital relay outputs Can be set to report different operation modes such as\u003c\/li\u003e\n\u003cli\u003erunning, warning, alarm, etc. RS 485 GENIbus interface CUE is equipped with a standard RS485 interface that can communicate with Grundfos control systems, and via a Grundfos gateway be connected to other bus systems such as LONWorks, Profibus, Modbus, etc.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAdd-on card\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAnalogue IO module offering:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTwo inputs for Pt100\/1000 temperature sensors (the card will Automatically detect if the sensor is a Pt100 or a Pt1000 sensor). One analogue 0\/4-20 mA input for an additional sensor. Motor filters\u003c\/li\u003e\n\u003cli\u003eAll CUE frequency converters deliver a non-sinusoidal voltage to the motor. In some cases it is required or desired to filter the output voltage to make it more sinusoidal,because:\u003c\/li\u003e\n\u003cli\u003eIt reduces the dv\/dt and the peak voltage delivered to the motor It reduces the acoustic noise generated in the motor windings It allows the use of long motor cables The following motor filters are available:\u003c\/li\u003e\n\u003cli\u003edU\/dt-filters\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSplit on 16 different filters covering:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower range: 11 to 250 kW\u003c\/li\u003e\n\u003cli\u003eVoltage range: 3x380-500 V and 3x525-690 V\u003c\/li\u003e\n\u003cli\u003eInsulation class: I P20\u003c\/li\u003e\n\u003cli\u003eAmbient temperature: Max. 45°C\u003c\/li\u003e\n\u003cli\u003eSine wave filters\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSplit on 23 different filters covering:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower range: 0.55 to 250 kW\u003c\/li\u003e\n\u003cli\u003eVoltage range: 1x200-240 V, 3x200-240 V, 3x380-\u003c\/li\u003e\n\u003cli\u003e500V and 3x525-690 V\u003c\/li\u003e\n\u003cli\u003eInsulation class: I P20\u003c\/li\u003e\n\u003cli\u003eAmbient temperature: Max. 45°C\u003c\/li\u003e\n\u003cli\u003e·\u003c\/li\u003e\n\u003cli\u003e·\u003c\/li\u003e\n\u003cli\u003e·\u003c\/li\u003e\n\u003cli\u003eSensors\u003c\/li\u003e\n\u003cli\u003eThe following sensors can be used in connection with\u003c\/li\u003e\n\u003cli\u003eCUE. All sensors are with 4-20 mA output signal.\u003c\/li\u003e\n\u003cli\u003ePressure sensors - up to 25 bar\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eDifferential pressure sensors\u003c\/li\u003e\n\u003cli\u003eDifferential temperature sensors\u003c\/li\u003e\n\u003cli\u003eFlow meters\u003c\/li\u003e\n\u003cli\u003ePotentiometer box for external setpoint setting\u003c\/li\u003e\n\u003cli\u003eGateways\u003c\/li\u003e\n\u003cli\u003eCUE is equipped with a standard RS485 GENIbus interface.\u003c\/li\u003e\n\u003cli\u003eGateways to convert to other bus standards can be\u003c\/li\u003e\n\u003cli\u003edelivered as an accessory.\u003c\/li\u003e\n\u003cli\u003eThe CIU family can convert to the most common\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003efieldbuses in the world:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCIU100 converts from GENIbus to LonWorks\u003c\/li\u003e\n\u003cli\u003eCIU150 converts from GENIbus to Profibus\u003c\/li\u003e\n\u003cli\u003eCIU200 converts from GENIbus to Modbus\u003c\/li\u003e\n\u003cli\u003eCIU250 is a GSM modem which can send SMS\u003c\/li\u003e\n\u003cli\u003emessages in case of alarms, etc.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOther accessories\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDry-running protection sensor LiqTec\u003c\/li\u003e\n\u003cli\u003eControl MPC – a multi-pump control system for control\u003c\/li\u003e\n\u003cli\u003eof parallel-connected CUE pump solutions.\u003c\/li\u003e\n\u003cli\u003eFOR PRICING ON \"OPTIONAL\" IP20 ENCLUSURE FILTER PART #97669869 AND SINE-WAVE FILTERS #96755032 PLEASE CONTACT US DIRECTLY.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":48799330959616,"sku":"91136800","price":6809.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/2222\/3360\/files\/cue_control_d143b413-ed07-41f5-8e0e-0a2565bc3dfa.jpg?v=1780613870","url":"https:\/\/waterpumpspro.com\/products\/91136800-cue-controls-variable-frequency-drives","provider":"Water Pumps Pro","version":"1.0","type":"link"}